Fix shutdown #107

Open
wants to merge 1 commit into
base: master
Choose a base branch
from
Open

Conversation

nicolalamacchia
Copy link

@nicolalamacchia nicolalamacchia commented Jan 11, 2021

Fixes #90 .

Right now the shutdown command is using the -r flag, which, when used, actually reboots a system. The correct command should be without that flag. See man 8 shutdown.

Remove the `-r` flag from the `shutdown` command
@cgherman
Copy link

Agree on this, it's a copy-paste mistake. I read through all the code and was confused about this line.

@fab1o
Copy link

fab1o commented Oct 17, 2022

why hasnt this been merged? @cgherman

@cgherman
Copy link

why hasnt this been merged? @cgherman

@RetroFlag can you please work on merging this for customers? It seems like an easy fix to verify, and there are several people in agreement on this...

@yoyojacky
Copy link

SafeShutdown.py里面的 poweroff 函数里面的os.system(’shutdown -r now') 是重启,你应该改成 os.system('shutdown -h now')
就是改一个字母, -r 改成 -h ,就搞定了。